Detailed Product Description
● Built-in high precision AC/DC/Harmonic standard source output;
● User-friendly interface comes by the use of Windows CE operating system kernel;
● Functions available such as calibration of AC sampling, transducer, and energy meter; auto-compute on the calibration error and follow-up report creating; report template can be defined by the users;
● Mouse and keyboard built in panel or external connection available;
● USB port convenient for data transmissio;
● Can be used as a standard meter to monitor the information of electric quantity of AC transmission line (available in KS905, KS906);
● Workable without PC, and provides RS232 and RJ45 to support PC communications. And the communication protocol is open to the users to make auto testing solution if necessary;
● Can be run offline, while providing network RJ45 port and RS232 port and PC communication, communication protocol and opening up to the user anduser-friendly program to test automatically;
● Compact size and portable carrying, convenient for on-site operation.
Technical Data of KS908
|
Voltage (AC) Output/Measure
|
|
Shift
|
100V/220/380V Auto switch
|
|
Adjusting range
|
0 ... 120%
|
|
Min Adjusting Unit
|
Shift x 0.01%
|
|
Resolution
|
Shift x 0.01%
|
|
Accuracy
|
0.05%RG (RG abbr. range)
|
|
Stability
|
0.01%/1min
|
|
Current (AC) Output/Measure
|
|
Shift
|
1A/5A/10AAuto switch
|
|
Adjusting range
|
0 ... 120%
|
|
Min Adjusting Unit
|
Shift x 0.01%
|
|
Resolution
|
Shift x 0.01%
|
|
Accuracy
|
0.05%RG
|
|
Stability
|
0.01%/1min
|
|
Power Output/Measure
|
|
Min Adjusting Unit
|
Shift x 0.01%
|
|
Resolution
|
Shift x 0.01%
|
|
Accuracy
|
0.05%RG (F>0.5)
|
|
Stability
|
0.01%/1min
|
|
Frequency Output/Measure
|
|
Range
|
45.000...65.000Hz
|
|
Min Adjusting Unit
|
0.001Hz
|
|
Accuracy
|
0.01%RD
|
|
Phase Output/Measure
|
|
Range
|
0.00° ... 359.99°
|
|
Min Adjusting Unit
|
0.01°
|
|
Resolution
|
0.01°
|
|
Accuracy
|
0.05°
|
|
Power factor Output/Measure
|
|
Output range
|
-1 ... 0 ... +1
|
|
Min Adjusting Unit
|
0.0001
|
|
Accuracy
|
0.0005
|
|
Harmonic Output/Measure
|
|
Set range
|
2 ... 31 times
|
|
Content
|
Voltage, Current≤30%( compared with Fundamental Wave)
|
|
Harmonic output accuracy
|
0.1%(2 ... 19 times, compared with Fundamental Wave)
|
|
Resolution
|
0.2%(20 ... 31 times, compared with Fundamental Wave)
|
|
Harmonic Phase
|
0.00° ... 359.99°
|
|
Output Voltage and Current distortion
|
|
<0.2%(non capacitance load)
|
|
Max AC Output Load
|
|
Voltage 25VA, Current 25VA
|
|
Voltage (DC) Output/Measure
|
|
Shift
|
100mV/1V/10V/30V/100V/300V
|
|
Adjusting range
|
0 ... 120%, 0 ... 110% at shift 750V
|
|
Min Adjusting Unit
|
Shift x 0.01%
|
|
Resolution
|
Shift x 0.01%
|
|
Accuracy
|
0.05%RG
|
|
Stability
|
0.01%/1min
|
|
Current (DC) Output/Measure
|
|
Shift
|
1mA/10mA/20mA
|
|
Adjusting range
|
0 ... 120%
|
|
Min Adjusting Unit
|
Shift x 0.01%
|
|
Resolution
|
Shift x 0.01%
|
|
Accuracy
|
0.05%RG
|
|
Stability
|
0.01%/1min
|
|
Max DC Output Load
|
|
Voltage 20VA, Current 25VA
|
|
DC measure
|
|
Voltage measure range
|
±10V
|
|
Current measure range
|
±20mA
|
|
Accuracy
|
0.01%RG
|
|
Index measure reference condition
|
|
Work temperature
|
0°C ... 40°C
|
|
Humidity range
|
≤85 %
|
|
Work power supply range
|
220VAC±15%, 50Hz
|
|
Weight
|
18KG
|
|
Dimensions
|
450(D)×180 (W)×380 (H) mm
|
|
Interface
|
RJ45, USB, PS/2, RS232
|
Major functions:
|
|
KS901 |
KS907 |
KS908 |
|
AC Standard Sources |
● |
● |
● |
|
DC Standard Sources |
● |
● |
● |
|
Power Standard Sources |
● |
● |
● |
|
Harmonic Standard Sources |
● |
● |
● |
|
Indicator Test |
● |
○ |
● |
|
Transmitter Test |
● |
● |
● |
|
Energy Meter Test |
● |
● |
● |
|
Rtu Test |
● |
● |
● |
|
Standard Meter |
○ |
○ |
● |
|
Sychronization test |
|
● |
● |
|
Tele-control, tele-communication |
|
● |
● |
Note: ● :With the corresponding function modules